Mylinking™ Network Tap Ib qho kev daws teeb meem zoo rau kev saib xyuas thiab kev txheeb xyuas cov ntaub ntawv
16 * GE 10/100 / 1000M BASE-T ntxiv rau 8 * GE SFP, Max 24Gbps, Bypass
Peb hais txog kev vam meej thiab qhia cov khoom tshiab rau hauv kev ua lag luam txhua xyoo rau Mylinking ™ Network Tap Ib qho kev daws teeb meem zoo rau kev saib xyuas thiab kev txheeb xyuas cov ntaub ntawv, ntseeg peb, koj tuaj yeem nrhiav kev daws teeb meem zoo dua rau kev lag luam tsheb.
Peb hais txog kev vam meej thiab qhia cov khoom tshiab rau hauv kev ua lag luam txhua xyoo rauCov kais dej tooj liab, Ethernet kais, Kev Hloov Kho Network, KAW SIV, Tam sim no peb tau yeej lub koob npe zoo ntawm cov neeg siv khoom txawv teb chaws thiab hauv tsev. Ua raws li txoj cai tswjfwm ntawm "credit oriented, customer first, high efficiency thiab mature services", peb zoo siab tos txais cov phooj ywg los ntawm txhua qhov chaw ntawm lub neej los koom tes nrog peb.
Mylinking™ Network Tap Ib qho kev daws teeb meem zoo rau kev saib xyuas thiab kev txheeb xyuas cov ntaub ntawv
Lub caij nyoog digital tau coj txog ntau cov ntaub ntawv uas tsis tau muaj dua los ntawm cov tes hauj lwm txhua ob. Rau cov lag luam thiab cov koom haum kom nyob ua ntej ntawm qhov kev ua si, nws yog qhov tseem ceeb kom muaj cov txheej txheem saib xyuas network uas muaj txiaj ntsig thiab txhim khu kev qha. Qhov no yog qhov uas Mylinking™ Network Tap los ua si - qhov kev daws teeb meem tshiab tsim los ua kom tau raws li qhov xav tau ntawm kev saib xyuas thiab kev txheeb xyuas cov ntaub ntawv. Mylinking™ Network Tap, tseem hu ua ML-TAP-2401B, muaj peev xwm ua tiav tau zoo txog li 24Gbps. Nrog lub zog zoo li no, nws qhib rau ntau yam kev xa tawm. Lub cuab yeej tuaj yeem ua haujlwm ua lub tshuab faib hluav taws xob, tso cai rau kev faib hluav taws xob ntawm cov tsheb khiav hauv network. Tsis tas li ntawd, nws tuaj yeem siv rau kev nkag mus rau qhov sib piv, ua rau muaj kev saib xyuas thiab kev txheeb xyuas cov tsheb khiav hauv network ntawm ntau lub cuab yeej.
Ib qho ntawm cov yam ntxwv tseem ceeb ntawm Mylinking™ Network Tap yog nws lub peev xwm los siv ua ib qho inline bypass series. Qhov no txhais tau tias nws tuaj yeem ntxig rau hauv qhov txuas network, kom ntseeg tau tias kev sib txuas network tsis muaj kev cuam tshuam txawm tias muaj hluav taws xob tsis ua haujlwm lossis lub cuab yeej ua haujlwm tsis zoo. Qhov no yog qhov hloov pauv rau cov lag luam uas vam khom lawv cov khoom siv network thiab tsis muaj peev xwm them taus lub sijhawm tsis ua haujlwm. Hauv cov kev xaiv sib txuas, Mylinking™ Network Tap zoo heev nrog nws txoj kev txhawb nqa rau qhov siab tshaj plaws ntawm 8 * GE SFP qhov thiab 16 * GE hluav taws xob qhov chaw nres nkoj. Cov qhov SFP yog qhov hloov pauv tau thiab tuaj yeem haum rau ob qho tib si Gigabit ib hom thiab ntau hom optical modules, nrog rau Gigabit hluav taws xob modules. Qhov kev hloov pauv no ua kom muaj kev sib raug zoo nrog ntau yam kev teeb tsa network, ua rau nws yog qhov kev xaiv txhim khu kev qha rau txhua lub koom haum.
Txhua lub interface ntawm Mylinking™ Network Tap txhawb nqa cov ntaub ntawv nkag thiab tawm, ua rau muaj kev sib koom ua ke zoo rau hauv cov chaw hauv network uas twb muaj lawm. Qhov no txhais tau tias cov neeg siv tuaj yeem yooj yim nkag mus rau hauv cov ntaub ntawv hauv network rau kev tshuaj xyuas lossis coj nws mus rau qhov chaw tshwj xeeb rau kev ua tiav ntxiv. Lub cuab yeej hom inline siv cov thev naus laus zis tiv thaiv kev tawg ntse, tiv thaiv txhua qhov kev cuam tshuam network los ntawm kev nce hluav taws xob lossis kev ua tsis tiav sai. Thaum nws los txog rau qhov yooj yim ntawm kev siv, Mylinking™ Network Tap ci ntsa iab. Nws lub interface intuitive tso cai rau kev teeb tsa sai thiab tsis muaj teeb meem, thiab nws muaj cov cuab yeej saib xyuas thiab kuaj mob. Lub cuab yeej kuj txhawb nqa kev tswj hwm chaw taws teeb, ua rau nws yooj yim rau cov thawj coj network los tswj thiab saib xyuas ntau Mylinking™ Network Taps los ntawm qhov chaw hauv nruab nrab.
Yog li, Mylinking™ Network Tap Ib qho Kev daws teeb meem ua tau zoo rau kev saib xyuas thiab kev txheeb xyuas cov ntaub ntawv ua ke ua ke kev ua tau zoo, kev hloov pauv tau yooj yim, thiab kev ntseeg siab los muab cov lag luam thiab cov koom haum nrog cov kev daws teeb meem zoo tshaj plaws rau kev saib xyuas thiab kev txheeb xyuas network. Txawm hais tias nws siv ua Ethernet Tap, Network Tap Switch, TAP Switch, lossis Copper TAP, lub cuab yeej no lub peev xwm ua tiav zoo thiab cov yam ntxwv siab heev ua kom ntseeg tau tias cov tsheb khiav hauv network tuaj yeem saib xyuas thiab txheeb xyuas tau zoo, ua rau muaj kev txiav txim siab zoo dua thiab txhim kho kev ruaj ntseg hauv network. Nyob ua ntej ntawm kev sib tw los ntawm kev nqis peev hauv Mylinking™ Network Tap - yav tom ntej ntawm kev saib xyuas network.
1- Txheej Txheem Cej Luam
- Ib lub cuab yeej ntes duab tag nrho ntawm lub network triffc nrog 16 * GE 10/100/1000M BASE-T chaw nres nkoj, thiab 8 * GE SFP qhov
- Ib qho cuab yeej tswj kev teem sijhawm ntawm cov ntaub ntawv tag nrho (kev ua tiav duplex Rx / Tx)
- Ib qho khoom siv ua ntej thiab rov faib khoom tag nrho (bandwidth bidirectional 24Gbps)
- Txhawb kev ntes & tau txais cov ntaub ntawv txuas los ntawm ntau qhov chaw sib txawv ntawm lub network
- Kev txhawb nqa kev sau thiab txais cov ntaub ntawv txuas los ntawm ntau lub switch routing nodes
- Txhawb kev ntes cov pob ntawv raw, txheeb xyuas, tshuaj xyuas, suav sau ua ke thiab cim
- Txhawb kom paub txog cov ntim sab saud tsis tseem ceeb ntawm Ethernet tsheb thauj mus los, txhawb txhua yam ntawm Ethernet pob ntawv protocols, thiab aslo 802.1q / q-in-q, IPX / SPX, MPLS, PPPO, ISL, GRE, PPTP thiab lwm yam protocol ntim
- Txhawb nqa raw packet forwarding rau kev saib xyuas xws li BigData Analysis, Protocol Analysis, Signaling Analysis, Security Analysis, Risk Management thiab lwm yam kev thov network traffic
- Kev txhawb nqa kev tshuaj xyuas cov ntaub ntawv hauv lub sijhawm tiag tiag, kev txheeb xyuas cov ntaub ntawv, thiab lwm yam.

ML-TAP-2401B
Mylinking™ lub network traffic replication aggregator tshiab yog cov khoom siv uas tau tso tawm dawb xws li kev nrhiav tsheb khiav, kev sib sau ua ke ntawm tsheb khiav, kev sib cais tsheb khiav thiab kev sib npaug ntawm cov khoom siv rau Gigabit Ethernet txuas. Lub network tap aggregator no tau tsim los rau hauv lub cav ntws mus rau kev taw qhia zoo, thaum lub network TAP ib txwm ntes tau tag nrho, txhua yam tuaj yeem sib txuas ua ke thiab SPAN chaw nres nkoj tsheb khiav. Raws li kev tswj hwm yooj yim rau kev hloov pauv network pob ntawv, kev rov ua dua, lossis kev sib sau ua ke, nws tuaj yeem xa cov hom tsheb khiav kom raug, kom ua tau raws li txhua yam khoom siv kev ruaj ntseg hauv network, kev tshuaj xyuas cov txheej txheem, thiab kev tshuaj xyuas cov teeb liab, xws li kev saib xyuas tsheb khiav hauv network lossis kev ruaj ntseg.
2- Daim duab qhia txog qhov system block

3- Txoj Cai Ua Haujlwm

4- Kev Txawj Ntse Txog Kev Ua Haujlwm Tsheb
6- Cov Lus Qhia Tshwj Xeeb
| Mylinking™ Network Tap NPB/TAP Cov Kev Ua Haujlwm | ||
| Kev Sib Txuas Lus Hauv Network | GE Chaw Nres Tsheb Hluav Taws Xob | 16 qhov chaw nres nkoj * 10/100 / 1000M BASE-T |
| Qhov SFP | 8 * GE SFP chaw nres nkoj, txhawb nqa GE Optical / Electrical Module | |
| Hom kev xa tawm | Hom kab hauv kab | txhawb nqa max 8 txoj kev / txuas * 10/100 / 1000M BASE-T inline hom |
| Cov ntaub ntawv saib xyuas SPAN | kev txhawb nqa siab tshaj 23 * SPAN cov tswv yim | |
| Kev Saib Xyuas Cov zis | kev txhawb nqa max 23 * saib xyuas cov zis | |
| Cov Haujlwm | Tag Nrho QTYs interface | 24 chaw nres nkoj |
| Kev muaj peev xwm ua haujlwm ceev ntawm kab | 24Gbps | |
| Kev rov ua dua / kev sib sau ua ke / kev faib tawm / kev xa mus / kev lim dej | Txhawb nqa | |
| Hom kab hauv kab thiab kev saib xyuas SPAN | Txhawb nqa | |
| Kev Sib Sau Ua Ke ntawm Tsheb Mus Rau Sab Sauv/Sab Hauv Qab | Txhawb nqa | |
| Kev Saib Xyuas Tsheb Mus Rau Sab Sauv/Down | Txhawb nqa | |
| Kev faib tawm raws li kev txheeb xyuas tsheb khiav | Txhawb nqa | |
| Kev faib tawm thiab kev lim dej raws li IP / protocol / port Tsib lub cim qhia txog kev tsheb khiav tuple | Txhawb nqa | |
| Optical interface ib leeg fiber kis tau tus mob | Txhawb nqa | |
| Txhawb nqa Ethernet encapsulation kev ywj pheej | Txhawb nqa | |
| BYPASS Function (Hom Inline) | Txhawb nqa | |
| Lub sijhawm hloov BYPASS (Hom Inline) | < 50ms | |
| Kev Ncua Sij Hawm Sab Network | < 100ns | |
| LinkReflect (Hom Inline) | Txhawb nqa | |
| Tsis muaj Flash Break thaum Power ON/OFF | Txhawb nqa | |
| Kev Tswj Xyuas Network CONSOLE | Txhawb nqa | |
| Kev Tswj Xyuas Network IP/WEB | Txhawb nqa | |
| Kev Tswj Xyuas Network SNMP V1/V2C | Txhawb nqa | |
| Kev Tswj Xyuas Network TELNET/SSH | Txhawb nqa | |
| Cov Txheej Txheem SYSLOG | Txhawb nqa | |
| Kev ua haujlwm txheeb xyuas tus neeg siv | Kev lees paub tus password raws li lub npe neeg siv | |
| Hluav Taws Xob (1 + 1 Redundant Power System-RPS) | Qhov ntsuas hluav taws xob | AC110-240V/DC-48V (Xaiv tau) |
| Lub zog zaus ntsuas | 50HZ | |
| Tam sim no cov tswv yim ntsuas | AC-3A / DC-10A | |
| Rated fais fab ua haujlwm | 100W | |
| Ib puag ncig | Kub Ua Haujlwm | 0-50 ℃ |
| Kub Cia Khoom | -20-70 ℃ | |
| Kev Ua Haujlwm Av noo | 10% -95%, Tsis-condensing | |
| Kev Teeb tsa Tus Neeg Siv | Kev Teeb Tsa Console | RS232 interface, 9600,8, N, 1 |
| Kev lees paub tus password | kev txhawb nqa | |
| Qhov Siab Khib | Qhov chaw khib (U) | 1U 485mm * 44.5mm * 350mm |
7- Cov Ntaub Ntawv Txog Kev Txiav Txim
ML-TAP-1201B mylinking™ Network Tap @
4 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, siab tshaj 12Gbps
ML-TAP-1601B mylinking™ Network Tap @
8 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, max 16Gbps
ML-TAP-2401B mylinking™ Network Tap @
16 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, siab tshaj 24Gbps
FYR: Kev Tswj Xyuas Cov Ntaub Ntawv Txog Kev Sib Txuas Lus Hauv Network
1- Rau Cov Ntaub Ntawv Qhov Chaw
•Kev Tau Txais: SPAN/Splitter
•Txoj Haujlwm Txheeb Ze: XX Switch, XX Internet Link, XX Rack Position
•Topology ntawm Network uas cuam tshuam
2- Rau Cov Ntsiab Lus Cov Ntaub Ntawv Faib Tawm
•Saib Khoom Lag Luam, Kev Sib Txuas Lus Lag Luam/Kev Pabcuam
•Txoj Cai Kev Faib Tawm Cov Ntaub Ntawv khi rau Lub Hom Phiaj Lag Luam
•Txheej txheem cej luam ntawm Txoj Cai Tswj Xyuas Cov Ntaub Ntawv
•Daim Ntawv Qhia Txog Cov Ntaub Ntawv
•Kev Tshem Tawm Cov Ntaub Ntawv Dua
• Kev Npog Cov Ntaub Ntawv
3- Rau Cov Ntaub Ntawv Tawm Mus
•Rau kev tswj cov ntaub ntawv tso zis ntawm cov cuab yeej khiav tsheb - IDS/Audit/NPM/APM
• Kev tswj cov ntaub ntawv qhov chaw ntawm lub cuab yeej (XX Machine Room/Rack Position/Output Point)
4- Rau Tag Nrho Cov Xwm Txheej
• Kev Saib Xyuas Kev Nkag Mus/Tawm Mus/Kev Txuas Hauv Is Taws Nem
• Lub vijtsam loj modular los tso saib cov ntaub ntawv tsheb khiav (Acquisition Point/Output point Traffic Trend, Packet Length & Type Distribution)
•Kev saib xyuas qhov xwm txheej ntawm txoj kev sib koom ua ke






