OEM Industrial 16 Chaw nres nkoj 10/100/1000M BASE-T Ethernet Tap Switch ntxiv rau 8 SFP GE Ports Network Tap Switch
16 * GE 10/100 / 1000M BASE-T ntxiv rau 8 * GE SFP, Max 24Gbps, Bypass
Peb lub tuam txhab hais kom ua raws li txoj cai zoo ntawm "khoom zoo yog lub hauv paus ntawm kev ciaj sia ntawm lub tuam txhab; kev txaus siab ntawm cov neeg yuav khoom yuav yog qhov pib thiab qhov kawg ntawm lub tuam txhab; kev txhim kho tas mus li yog kev nrhiav neeg ua haujlwm tas mus li "thiab lub hom phiaj tas mus li ntawm "lub koob npe nrov ua ntej, tus neeg yuav khoom ua ntej" rau OEM Industrial 16 Ports 10/100/1000M BASE-TEthernet Tap Switchntxiv rau 8 SFP GE Ports Network Tap Switch, Feem ntau rau feem ntau ntawm cov neeg siv lag luam thiab cov tub luam kom muab cov khoom zoo tshaj plaws thiab lub tuam txhab zoo heev. Zoo siab txais tos los koom nrog peb, cia peb tsim kho tshiab ua ke, kom npau suav ya.
Peb lub tuam txhab hais tias txhua txoj cai zoo ntawm "khoom zoo yog lub hauv paus ntawm kev ciaj sia ntawm lub tuam txhab; kev txaus siab ntawm cov neeg siv khoom yuav yog qhov pib thiab qhov kawg ntawm lub tuam txhab; kev txhim kho tas mus li yog kev nrhiav neeg ua haujlwm tas mus li" thiab lub hom phiaj tas mus li ntawm "lub koob npe nrov ua ntej, cov neeg siv khoom ua ntej" rauTuam Tshoj Network Tap Switch, Tooj Liab Network Tap, Ethernet Tap Switch, Network Core Switch, Ua haujlwm hnyav kom ua tiav kev vam meej, kev tsim kho tshiab hauv kev lag luam, ua txhua yam kev rau siab rau thawj-chav kawm lag luam. Peb sim peb qhov zoo tshaj plaws los tsim cov qauv kev tswj hwm kev tshawb fawb, kom kawm tau ntau yam kev paub dhau los, los tsim cov khoom siv tsim khoom siab heev thiab cov txheej txheem tsim khoom, los tsim cov khoom zoo thawj zaug, tus nqi tsim nyog, kev pabcuam zoo, kev xa khoom sai, los nthuav qhia koj tsim tus nqi tshiab.
1- Txheej Txheem Cej Luam
- Ib lub cuab yeej ntes duab tag nrho ntawm lub network triffc nrog 16 * GE 10/100/1000M BASE-T chaw nres nkoj, thiab 8 * GE SFP qhov
- Ib qho cuab yeej tswj kev teem sijhawm ntawm cov ntaub ntawv tag nrho (kev ua tiav duplex Rx / Tx)
- Ib qho khoom siv ua ntej thiab rov faib khoom tag nrho (bandwidth bidirectional 24Gbps)
- Txhawb kev ntes & tau txais cov ntaub ntawv txuas los ntawm ntau qhov chaw sib txawv ntawm lub network
- Kev txhawb nqa kev sau thiab txais cov ntaub ntawv txuas los ntawm ntau lub switch routing nodes
- Txhawb kev ntes cov pob ntawv raw, txheeb xyuas, tshuaj xyuas, suav sau ua ke thiab cim
- Txhawb kom paub txog cov ntim sab saud tsis tseem ceeb ntawm Ethernet tsheb thauj mus los, txhawb txhua yam ntawm Ethernet pob ntawv protocols, thiab aslo 802.1q / q-in-q, IPX / SPX, MPLS, PPPO, ISL, GRE, PPTP thiab lwm yam protocol ntim
- Txhawb nqa raw packet forwarding rau kev saib xyuas xws li BigData Analysis, Protocol Analysis, Signaling Analysis, Security Analysis, Risk Management thiab lwm yam kev thov network traffic
- Kev txhawb nqa kev tshuaj xyuas cov ntaub ntawv hauv lub sijhawm tiag tiag, kev txheeb xyuas cov ntaub ntawv, thiab lwm yam.

ML-TAP-2401B
Mylinking™ lub network traffic replication aggregator tshiab yog cov khoom siv uas tau tso tawm dawb xws li kev nrhiav tsheb khiav, kev sib sau ua ke ntawm tsheb khiav, kev sib cais tsheb khiav thiab kev sib npaug ntawm cov khoom siv rau Gigabit Ethernet txuas. Lub network tap aggregator no tau tsim los rau hauv lub cav ntws mus rau kev taw qhia zoo, thaum lub network TAP ib txwm ntes tau tag nrho, txhua yam tuaj yeem sib txuas ua ke thiab SPAN chaw nres nkoj tsheb khiav. Raws li kev tswj hwm yooj yim rau kev hloov pauv network pob ntawv, kev rov ua dua, lossis kev sib sau ua ke, nws tuaj yeem xa cov hom tsheb khiav kom raug, kom ua tau raws li txhua yam khoom siv kev ruaj ntseg hauv network, kev tshuaj xyuas cov txheej txheem, thiab kev tshuaj xyuas cov teeb liab, xws li kev saib xyuas tsheb khiav hauv network lossis kev ruaj ntseg.
2- Daim duab qhia txog qhov system block

3- Txoj Cai Ua Haujlwm

4- Kev Txawj Ntse Txog Kev Ua Haujlwm Tsheb
6- Cov Lus Qhia Tshwj Xeeb
| Mylinking™ Network Tap NPB/TAP Cov Kev Ua Haujlwm | ||
| Kev Sib Txuas Lus Hauv Network | GE Chaw Nres Tsheb Hluav Taws Xob | 16 qhov chaw nres nkoj * 10/100 / 1000M BASE-T |
| Qhov SFP | 8 * GE SFP chaw nres nkoj, txhawb nqa GE Optical / Electrical Module | |
| Hom kev xa tawm | Hom kab hauv kab | txhawb nqa max 8 txoj kev / txuas * 10/100 / 1000M BASE-T inline hom |
| Cov ntaub ntawv saib xyuas SPAN | kev txhawb nqa siab tshaj 23 * SPAN cov tswv yim | |
| Kev Saib Xyuas Cov zis | kev txhawb nqa max 23 * saib xyuas cov zis | |
| Cov Haujlwm | Tag Nrho QTYs interface | 24 chaw nres nkoj |
| Kev muaj peev xwm ua haujlwm ceev ntawm kab | 24Gbps | |
| Kev rov ua dua / kev sib sau ua ke / kev faib tawm / kev xa mus / kev lim dej | Txhawb nqa | |
| Hom kab hauv kab thiab kev saib xyuas SPAN | Txhawb nqa | |
| Kev Sib Sau Ua Ke ntawm Tsheb Mus Rau Sab Sauv/Sab Hauv Qab | Txhawb nqa | |
| Kev Saib Xyuas Tsheb Mus Rau Sab Sauv/Down | Txhawb nqa | |
| Kev faib tawm raws li kev txheeb xyuas tsheb khiav | Txhawb nqa | |
| Kev faib tawm thiab kev lim dej raws li IP / protocol / port Tsib lub cim qhia txog kev tsheb khiav tuple | Txhawb nqa | |
| Optical interface ib leeg fiber kis tau tus mob | Txhawb nqa | |
| Txhawb nqa Ethernet encapsulation kev ywj pheej | Txhawb nqa | |
| BYPASS Function (Hom Inline) | Txhawb nqa | |
| Lub sijhawm hloov BYPASS (Hom Inline) | < 50ms | |
| Kev Ncua Sij Hawm Sab Network | < 100ns | |
| LinkReflect (Hom Inline) | Txhawb nqa | |
| Tsis muaj Flash Break thaum Power ON/OFF | Txhawb nqa | |
| Kev Tswj Xyuas Network CONSOLE | Txhawb nqa | |
| Kev Tswj Xyuas Network IP/WEB | Txhawb nqa | |
| Kev Tswj Xyuas Network SNMP V1/V2C | Txhawb nqa | |
| Kev Tswj Xyuas Network TELNET/SSH | Txhawb nqa | |
| Cov Txheej Txheem SYSLOG | Txhawb nqa | |
| Kev ua haujlwm txheeb xyuas tus neeg siv | Kev lees paub tus password raws li lub npe neeg siv | |
| Hluav Taws Xob (1 + 1 Redundant Power System-RPS) | Qhov ntsuas hluav taws xob | AC110-240V/DC-48V (Xaiv tau) |
| Lub zog zaus ntsuas | 50HZ | |
| Tam sim no cov tswv yim ntsuas | AC-3A / DC-10A | |
| Rated fais fab ua haujlwm | 100W | |
| Ib puag ncig | Kub Ua Haujlwm | 0-50 ℃ |
| Kub Cia Khoom | -20-70 ℃ | |
| Kev Ua Haujlwm Av noo | 10% -95%, Tsis-condensing | |
| Kev Teeb tsa Tus Neeg Siv | Kev Teeb Tsa Console | RS232 interface, 9600,8, N, 1 |
| Kev lees paub tus password | kev txhawb nqa | |
| Qhov Siab Khib | Qhov chaw khib (U) | 1U 485mm * 44.5mm * 350mm |
7- Cov Ntaub Ntawv Txog Kev Txiav Txim
ML-TAP-1201B mylinking™ Network Tap @
4 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, siab tshaj 12Gbps
ML-TAP-1601B mylinking™ Network Tap @
8 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, max 16Gbps
ML-TAP-2401B mylinking™ Network Tap @
16 * GE 10/100 / 1000M BASE-T chaw nres nkoj, ntxiv rau 8 * GE SFP chaw nres nkoj, siab tshaj 24Gbps
FYR: Kev Tswj Xyuas Cov Ntaub Ntawv Txog Kev Sib Txuas Lus Hauv Network
1- Rau Cov Ntaub Ntawv Qhov Chaw
•Kev Tau Txais: SPAN/Splitter
•Txoj Haujlwm Txheeb Ze: XX Switch, XX Internet Link, XX Rack Position
•Topology ntawm Network uas cuam tshuam
2- Rau Cov Ntsiab Lus Cov Ntaub Ntawv Faib Tawm
•Saib Khoom Lag Luam, Kev Sib Txuas Lus Lag Luam/Kev Pabcuam
•Txoj Cai Kev Faib Tawm Cov Ntaub Ntawv khi rau Lub Hom Phiaj Lag Luam
•Txheej txheem cej luam ntawm Txoj Cai Tswj Xyuas Cov Ntaub Ntawv
•Daim Ntawv Qhia Txog Cov Ntaub Ntawv
•Kev Tshem Tawm Cov Ntaub Ntawv Dua
• Kev Npog Cov Ntaub Ntawv
3- Rau Cov Ntaub Ntawv Tawm Mus
•Rau kev tswj cov ntaub ntawv tso zis ntawm cov cuab yeej khiav tsheb - IDS/Audit/NPM/APM
• Kev tswj cov ntaub ntawv qhov chaw ntawm lub cuab yeej (XX Machine Room/Rack Position/Output Point)
4- Rau Tag Nrho Cov Xwm Txheej
• Kev Saib Xyuas Kev Nkag Mus/Tawm Mus/Kev Txuas Hauv Is Taws Nem
• Lub vijtsam loj modular los tso saib cov ntaub ntawv tsheb khiav (Acquisition Point/Output point Traffic Trend, Packet Length & Type Distribution)
•Kev saib xyuas qhov xwm txheej ntawm txoj kev sib koom ua ke







